id: 33777
Назва: Results of numerical modeling of three-pipe heat exchanger for livestock premises
Автори: Yaropud V., Kupchuk I., Burlaka S., Rutkevych V.
Ключові слова: microclimate, livestock premises, ventilation, heat utilizer, automation, parameters, researches, dependencies
Дата публікації: 2023-09-18 12:52:26
Останні зміни: 2023-09-18 12:52:26
Рік видання: 2023
Аннотація: Developed a three-pipe heat recovery system containing three coaxially installed pipes (inner, middle and outer), a condensate drain pipe that passes through the outer pipe and is located at the bottom of the middle pipe, an exhaust shaft that passes through the outer pipe, supply and discharge air filter, which is additionally equipped with an ultraviolet lamp. As a result of numerical modeling of the heat recovery device, the distribution of the temperature and vector velocity fields is established.
URI: http://socrates.vsau.edu.ua/repository/getfile.php/33777.pdf
Тип виданя: Статті Scopus/Web of Science
Видавництво: Przeglad Elektrotechniczny. 2023. Vol. 99, № 9. P. 72-75. DOI:10.15199/48.2023.09.12
Розташовується в колекціях :
Ким внесений: Адміністратор
Файл : 33777.pdf Розмір : 1010489 байт Формат : Adobe PDF Доступ : Загально доступний

Збільшити

Система "Сократ"  |   Офіційний сайт Copyright © 2013, математика Є.А.Паламарчук, дизайн Р.О.Яцковська